Designed to convert an optical signal into an electric at speeds up to 2.5 Gb/s.
APPLICATION
Fiber-optic communication lines.
FEATURES
Wide operating range: 50 Mbit/s — 2.5 Gbit/s. The presence of paraphase output and the detector signal loss
SPECIFICATION
Wavelength, µm...............................1,2-1,6
Transfer rate, Gbit/sec............................2,5
The minimum sensitivity, dBm, min….-20
Typical sensitivity, dBm ......................-22
Maximum sensitivity, dBm ..................-24
Dynamic range, dBm, min …………....20
Current consumption , mA, max……..100
Power supply , V.............................+5±0,25
Temperature range, °C..................... -40+60
The length of optical fiber with an optical connector under request, m ....1±0,1
DESCRIPTION
Module is made on standard glass-to-metal basis of hybrid integrated technology. Includes a section of multimode or single mode optical fiber connector type FC, SC or ST, pin-photodetector, transimpedance amplifier and the detector of signal loss (the "flag").Back to the section