Designed to operate in digital optical receiver modules with TTL output signals in the equipment of fiber-optic communications lines with transfer rate up to 125 Mbit/s.
FEATURES
Digital paraphase output, built-in diagnostic scheme is the presence of optical radiation
SPECIFICATION
The parameter name Value
1 The output voltage at the minimum input signal (0,4 mA), V
- voltage of logic zero, max ………………………............. 0,5
- voltage of logic unit, min ……………………………… .. 2,4
2 The output voltage at the maximum input signal (32 mA), V
- voltage of logic zero, max ………………….……. ….. 0,5
- voltage of logic unit, min ……………….…… …….. 2,4
3 Duration of received pulses, ns ……….……... from 8 to 100
4 Levels of output electric signals ………………………... TTL
5 Power consumption, W, max …………………...........… 0,9
6 Supply voltage, V ………………………………..… 5±0,25
7 Operating temperature range, °С …...… …. -40 … +55
8 Dimensions, mm ………….………………….…. 19,4×22,0
9 Weight microassembly, g, max ……. …………………… 12
Note. The sensitivity of the optical receiver module -33 dBm for inclusion in the microassembly pin-photodiode with a sensitivity of min 0.8 A/W and a capacity of max 0.4pF.
Back to the section