About
News
Scientific activity
Products
Services
Contacts
PURPOSE
Designed for the registration of pulsed laser radiation with a valuation of the front output pulse relative to the starting pulse in a wide range of input optical power.
APPLICATION
Laser ranging and location.
SPECIFICATION
|
Parameter Description |
Norm |
| Area of spectral sensitivity on the level of the level 0,5, μm | 1,0…1,6 |
| The range of the laser pulse, ns | 6-30 |
| The threshold sensitivity for the probability of reliable reception of 0.9, W, max | 10-7 |
| The probability of false alarm for the time of 5...150 μs | 10-3 |
| The dynamic range of power of laser pulses, dB, min | 43 |
| Time shift of the output electric pulse in the dynamic range, ns, max | 15 |
| Supply voltage, B, (mA, max) | +12…+28(80) |
| The deviation of the center of photosensitive part of photodetector relative to the base boundaries, μm, max |
|
| Operating temperature range, °C | -40...+60 |
FEATURES
The module has: built-in sensitivity control, the output pulse amplitude CMOS level, the diameter of the sensitive area of the photodiode p-In 150 microns, or on request.